Honeywell aquastat l4006a manual






















Honeywell LA,B,E,H Aquastat® Controllers Installation Manual Honeywell LA APPLICATION. These boiler-mounted, immersion type controllers operate in response to temperature changes in hydronic heating systems. LA breaks the circuit on a temperature rise to the control setting. It is used for high limit or low limit www.doorway.ru: PDF. LA Aquastat Controller fits the old immersion well spud, this immersion well does not need to be replaced. 2. If the immersion well is to be replaced and if the system is filled, drain the system to a point below the boiler tapping. 3. Remove plug (or old immersion well) from boiler tapping. 4. Install new immersion well (not included). When a. L,7,8; L,7,8 AQUASTATfi CONTROLLERS Š9 6 a Some models include copper well or fitting; specify when www.doorway.ru specify boiler tapping size 1/2 or 3/4 in. NPT and insulation depth. b Manual reset (trip-free) switch breaks circuit and locks out when controlled medium reaches setpoint. Controlled temperature.


Resideo LA - High or Low Limit Aquastat, Degree(F) range, Degree(F) Adj Differential - Aquastat+ Controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Features Totally enclosed Micro Switch snap-acting switches operate on temperature rise to setpoint. aquastat¨ controller circulator la or la low limit aquastat¨ controller l1 (hot) l2 la or la high limit aquastat¨ controller 24 volt thermostat raa switching relay protectorelay¨ control power supply. provide disconnect means and overload protection as required. use le for manual reset. 1 2 ma tt xx4 2 1 1 2. LA,B,E,L; LA,G,H REMOTE BULB AQUASTAT ® CONTROLLERS. The Aquastat® controller can be remotely mounted— either vertically on a wall or panel, or directly on the boiler, tank, or vessel. If the system is filled, drain the system to a point below the boiler tapping, or to wherever the sensing bulb is to be installed. Mounting the Case.


Honeywell LA,B,E,H Aquastat® Controllers Installation Manual Honeywell LA APPLICATION. These boiler-mounted, immersion type controllers operate in response to temperature changes in hydronic heating systems. LA breaks the circuit on a temperature rise to the control setting. It is used for high limit or low limit control. TRADELINE Models: LA,B,E; LE; LC; LA Aquastat Controllers. TRADELINE Features Available: TRADELINE package with cross reference label and special instructions. Some Tradeline models include well. Factory-set stops at °F, °F, or °F (82°C, °C, or °C). Vertical or horizontal mount. Tube of heat-conductive compound. Honeywell Aquastat LA Installation Instructions Manual. Download Installation instructions manual of Honeywell Aquastat LA Thermostat for Free or View it Online on www.doorway.ru This version of Honeywell Aquastat LA Manual compatible with such list of devices, as: Aquastat LA, Aquastat LB, Aquastat LE, Aquastat LH.

0コメント

  • 1000 / 1000